{"id":6495,"date":"2024-11-21T13:59:17","date_gmt":"2024-11-21T12:59:17","guid":{"rendered":"https:\/\/leichtbau.dlr.de\/technology-under-test-leak-proof-hydrogen-tanks-thanks-to-bulge-test-bench"},"modified":"2025-08-13T12:57:11","modified_gmt":"2025-08-13T10:57:11","slug":"technology-under-test-leak-proof-hydrogen-tanks-thanks-to-bulge-test-bench","status":"publish","type":"post","link":"https:\/\/leichtbau.dlr.de\/en\/technology-under-test-leak-proof-hydrogen-tanks-thanks-to-bulge-test-bench","title":{"rendered":"Technology under test: leak-proof hydrogen tanks thanks to bulge test bench"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text]<strong>The global climate targets require, among other things, a massive reduction in greenhouse gas emissions, including in aviation. Hydrogen as an alternative energy source for aircraft is a promising solution as, unlike jet-fuel, it causes hardly any direct climate-damaging emissions. One of the biggest challenges is the storage of liquid hydrogen (LH2) at extremely low temperatures. Efficient and safe LH2 storage systems are crucial and lightweight construction with carbon fibre reinforced plastics (CFRP) plays an important role.   <\/strong>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4>Challenges of the CFRP tank<\/h4>\n<p>Current LH2 aircraft tank concepts are based on the proven principle of the thermos flask: a vacuum between two tank walls with special insulation (e.g. using a multi-layer) thermally isolates the surroundings and minimises heat loss. This ensures high storage efficiency.<br \/>\nIn addition, leaks in the tank must be prevented at all costs. The large temperature difference between the production of the tank structure in the autoclave at up to 180 \u00b0C and operation at -253 \u00b0C causes considerable thermal residual stresses in the fibre composite. This can result in microcracks. Combined thermo-mechanical stresses can even cause micro-crack networks with leakage paths through the tank wall. If liquid hydrogen escapes, the high rate of expansion during the transition to the gas phase can lead to a considerable increase in pressure in the insulation and even to structural failure.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space]<style type=\"text\/css\" data-type=\"the7_shortcodes-inline-css\">.shortcode-single-image-wrap.shortcode-single-image-857edc992c2c5220fb736d1e3e931144.enable-bg-rollover .rollover i,\n.shortcode-single-image-wrap.shortcode-single-image-857edc992c2c5220fb736d1e3e931144.enable-bg-rollover .rollover-video i {\n  background: -webkit-linear-gradient();\n  background: linear-gradient();\n}\n.shortcode-single-image-wrap.shortcode-single-image-857edc992c2c5220fb736d1e3e931144 .rollover-icon {\n  font-size: 32px;\n  color: #ffffff;\n  min-width: 44px;\n  min-height: 44px;\n  line-height: 44px;\n  border-radius: 100px;\n  border-style: solid;\n  border-width: 0px;\n}\n.dt-icon-bg-on.shortcode-single-image-wrap.shortcode-single-image-857edc992c2c5220fb736d1e3e931144 .rollover-icon {\n  background: rgba(255,255,255,0.3);\n  box-shadow: none;\n}\n<\/style><div class=\"shortcode-single-image-wrap shortcode-single-image-857edc992c2c5220fb736d1e3e931144 alignnone caption-on  enable-bg-rollover dt-icon-bg-off\" style=\"margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; width:1000px;\"><div class=\"shortcode-single-image\"><div class=\"fancy-media-wrap  layzr-bg\" style=\"\"><img fetchpriority=\"high\" decoding=\"async\" class=\"preload-me lazy-load aspect\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D&#39;http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg&#39;%20viewBox%3D&#39;0%200%201000%20642&#39;%2F%3E\" data-src=\"https:\/\/leichtbau.dlr.de\/wp-content\/uploads\/2024\/10\/CFK_Tank_JK_03-1000x642.png\" data-srcset=\"https:\/\/leichtbau.dlr.de\/wp-content\/uploads\/2024\/10\/CFK_Tank_JK_03-1000x642.png 1000w, https:\/\/leichtbau.dlr.de\/wp-content\/uploads\/2024\/10\/CFK_Tank_JK_03.png 2000w\" loading=\"eager\" sizes=\"(max-width: 1000px) 100vw, 1000px\" width=\"1000\" height=\"642\"  data-dt-location=\"https:\/\/leichtbau.dlr.de\/en\/leckagesichere-wasserstofftanks-dank-bulge-pruefstand\/cfk_tank_jk_03\" style=\"--ratio: 1000 \/ 642;\" alt=\"\" \/><\/div><\/div><div class=\"shortcode-single-caption\">Wirkprinzip des Bulge-Pr\u00fcfstands  \n<\/div><\/div>[vc_empty_space][vc_column_text]There are three main concepts for making hydrogen tanks leak-proof:<\/p>\n<ol>\n<li><strong>Liner concept<\/strong>: A metal or plastic barrier is used here. However, this method does not solve the actual problem of microcracks. Furthermore, a liner also increases the weight of the tank and the complexity of production and assembly.  <\/li>\n<li><strong>Thin-ply concept<\/strong>: This concept uses particularly thin laminate layers (thin-plies), which are intended to prevent cracking due to their increased crack resistance.<\/li>\n<li><strong>Cryo-optimised materials<\/strong>: This is the most promising concept, as it aims to prevent the onset micro-cracks using specially developed materials. This eliminates the need for additional barrier layers, which saves weight and production costs. <\/li>\n<\/ol>\n<p>The combination of thermal and mechanical loads during operation represents a major challenge for tank development &#8211; especially when it comes to precisely simulating these conditions on a test bench, particularly as these loads act in different directions and occur both cyclically and constantly. Classic universal testing machines reach their limits here, which is why new test methods are required.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space]<style type=\"text\/css\" data-type=\"the7_shortcodes-inline-css\">.shortcode-single-image-wrap.shortcode-single-image-a047c6a4927ed775e3a2a1c5fdf3290f.enable-bg-rollover .rollover i,\n.shortcode-single-image-wrap.shortcode-single-image-a047c6a4927ed775e3a2a1c5fdf3290f.enable-bg-rollover .rollover-video i {\n  background: -webkit-linear-gradient();\n  background: linear-gradient();\n}\n.shortcode-single-image-wrap.shortcode-single-image-a047c6a4927ed775e3a2a1c5fdf3290f .rollover-icon {\n  font-size: 32px;\n  color: #ffffff;\n  min-width: 44px;\n  min-height: 44px;\n  line-height: 44px;\n  border-radius: 100px;\n  border-style: solid;\n  border-width: 0px;\n}\n.dt-icon-bg-on.shortcode-single-image-wrap.shortcode-single-image-a047c6a4927ed775e3a2a1c5fdf3290f .rollover-icon {\n  background: rgba(255,255,255,0.3);\n  box-shadow: none;\n}\n<\/style><div class=\"shortcode-single-image-wrap shortcode-single-image-a047c6a4927ed775e3a2a1c5fdf3290f alignnone caption-on  enable-bg-rollover dt-icon-bg-off\" style=\"margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; width:1000px;\"><div class=\"shortcode-single-image\"><div class=\"fancy-media-wrap  layzr-bg\" style=\"\"><img decoding=\"async\" class=\"preload-me lazy-load aspect\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D&#39;http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg&#39;%20viewBox%3D&#39;0%200%201000%20797&#39;%2F%3E\" data-src=\"https:\/\/leichtbau.dlr.de\/wp-content\/uploads\/2024\/10\/Bulge1_DSC_5517-1000x797.png\" data-srcset=\"https:\/\/leichtbau.dlr.de\/wp-content\/uploads\/2024\/10\/Bulge1_DSC_5517-1000x797.png 1000w, https:\/\/leichtbau.dlr.de\/wp-content\/uploads\/2024\/10\/Bulge1_DSC_5517-2000x1594.png 2000w\" loading=\"eager\" sizes=\"(max-width: 1000px) 100vw, 1000px\" width=\"1000\" height=\"797\"  data-dt-location=\"https:\/\/leichtbau.dlr.de\/en\/leckagesichere-wasserstofftanks-dank-bulge-pruefstand\/bulge1_dsc_5517\" style=\"--ratio: 1000 \/ 797;\" alt=\"\" \/><\/div><\/div><div class=\"shortcode-single-caption\">Gesamtansicht des Bulge-Pr\u00fcfstands <\/div><\/div>[vc_empty_space][vc_column_text]<\/p>\n<h4>The bulge test rig<\/h4>\n<p>Detecting microcracks and microcrack networks in the tank structure is extremely difficult. Using traditional methods such as microscopy or CT analysis, it is often a matter of luck to find the right spot. The bulge test rig offers a decisive advantage here. It makes it possible to reliably test the tightness of CFRP test specimens. The test specimen is clamped in a clamping device and cooled to cryogenic temperatures. Helium is then fed into one chamber at up to 20 bar, while a vacuum (1E-02 mbar) prevails in the other chamber. The resulting pressure difference causes the test specimen to deform in a similar way to a real tank. A mass spectrometer measures the helium leakage flow as soon as the test specimen starts to leak. This allows the limits of the material to be precisely determined. The highlight is the use of helium as a substitute gas for gaseous hydrogen for leak detection and liquid nitrogen (LN2) as a substitute medium for LH2 for cooling. Similar molecular and atomic sizes and comparable boiling points (-253 \u00b0C vs. -196 \u00b0C) ensure that the results can be transferred with significantly less effort. With this simplified procedure, important findings can be obtained quickly, e.g. with regard to the evaluation of the concepts described above for a leak-free LH2 tank. The solutions developed in this way must then finally prove their suitability under LH2 conditions.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_empty_space][vc_column_text]<\/p>\n<h4>Future prospects<\/h4>\n<p>The development of LH2 tanks made of CFRP raises many questions. The approach presented here helps to answer fundamental questions safely, cost-effectively and time-efficiently and to accelerate tank development. In addition to answering questions about the material, the bulge test bench can also be used to test feedthrough concepts for the tank.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;]<style type=\"text\/css\" data-type=\"the7_shortcodes-inline-css\">.shortcode-single-image-wrap.shortcode-single-image-168d307a420a255a2c4fb467e3bdd409.enable-bg-rollover .rollover i,\n.shortcode-single-image-wrap.shortcode-single-image-168d307a420a255a2c4fb467e3bdd409.enable-bg-rollover .rollover-video i {\n  background: -webkit-linear-gradient();\n  background: linear-gradient();\n}\n.shortcode-single-image-wrap.shortcode-single-image-168d307a420a255a2c4fb467e3bdd409 .rollover-icon {\n  font-size: 32px;\n  color: #ffffff;\n  min-width: 44px;\n  min-height: 44px;\n  line-height: 44px;\n  border-radius: 100px;\n  border-style: solid;\n  border-width: 0px;\n}\n.dt-icon-bg-on.shortcode-single-image-wrap.shortcode-single-image-168d307a420a255a2c4fb467e3bdd409 .rollover-icon {\n  background: rgba(255,255,255,0.3);\n  box-shadow: none;\n}\n<\/style><div class=\"shortcode-single-image-wrap shortcode-single-image-168d307a420a255a2c4fb467e3bdd409 alignnone caption-on  enable-bg-rollover dt-icon-bg-off\" style=\"margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; width:250px;\"><div class=\"shortcode-single-image\"><div class=\"fancy-media-wrap  layzr-bg\" style=\"\"><img decoding=\"async\" class=\"preload-me lazy-load aspect\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D&#39;http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg&#39;%20viewBox%3D&#39;0%200%20250%20375&#39;%2F%3E\" data-src=\"https:\/\/leichtbau.dlr.de\/wp-content\/uploads\/2024\/10\/DSC2172-250x375.png\" data-srcset=\"https:\/\/leichtbau.dlr.de\/wp-content\/uploads\/2024\/10\/DSC2172-250x375.png 250w, https:\/\/leichtbau.dlr.de\/wp-content\/uploads\/2024\/10\/DSC2172-500x750.png 500w\" loading=\"eager\" sizes=\"(max-width: 250px) 100vw, 250px\" width=\"250\" height=\"375\"  data-dt-location=\"https:\/\/leichtbau.dlr.de\/en\/leckagesichere-wasserstofftanks-dank-bulge-pruefstand\/_dsc2172\" style=\"--ratio: 250 \/ 375;\" alt=\"\" \/><\/div><\/div><div class=\"shortcode-single-caption\">Detailansicht des Bulge-Pr\u00fcfstands <\/div><\/div>[\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;]<style type=\"text\/css\" data-type=\"the7_shortcodes-inline-css\">.shortcode-single-image-wrap.shortcode-single-image-073e40f7c971a55c5cabd11abface866.enable-bg-rollover .rollover i,\n.shortcode-single-image-wrap.shortcode-single-image-073e40f7c971a55c5cabd11abface866.enable-bg-rollover .rollover-video i {\n  background: -webkit-linear-gradient();\n  background: linear-gradient();\n}\n.shortcode-single-image-wrap.shortcode-single-image-073e40f7c971a55c5cabd11abface866 .rollover-icon {\n  font-size: 32px;\n  color: #ffffff;\n  min-width: 44px;\n  min-height: 44px;\n  line-height: 44px;\n  border-radius: 100px;\n  border-style: solid;\n  border-width: 0px;\n}\n.dt-icon-bg-on.shortcode-single-image-wrap.shortcode-single-image-073e40f7c971a55c5cabd11abface866 .rollover-icon {\n  background: rgba(255,255,255,0.3);\n  box-shadow: none;\n}\n<\/style><div class=\"shortcode-single-image-wrap shortcode-single-image-073e40f7c971a55c5cabd11abface866 alignnone  enable-bg-rollover dt-icon-bg-off\" style=\"margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; width:250px;\"><div class=\"shortcode-single-image\"><div class=\"fancy-media-wrap  layzr-bg\" style=\"\"><img decoding=\"async\" class=\"preload-me lazy-load aspect\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D&#39;http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg&#39;%20viewBox%3D&#39;0%200%20250%20257&#39;%2F%3E\" data-src=\"https:\/\/leichtbau.dlr.de\/wp-content\/uploads\/2024\/11\/BMWK_Logo-mit-Foerderzusatz_de-250x257.png\" data-srcset=\"https:\/\/leichtbau.dlr.de\/wp-content\/uploads\/2024\/11\/BMWK_Logo-mit-Foerderzusatz_de-250x257.png 250w, https:\/\/leichtbau.dlr.de\/wp-content\/uploads\/2024\/11\/BMWK_Logo-mit-Foerderzusatz_de-500x514.png 500w\" loading=\"eager\" sizes=\"(max-width: 250px) 100vw, 250px\" width=\"250\" height=\"257\"  data-dt-location=\"https:\/\/leichtbau.dlr.de\/en\/strukturelles-kleben-haelt-den-fluessigwasserstofftank-im-flugzeug-zusammen\/bmwk_logo-mit-foerderzusatz_de\" style=\"--ratio: 250 \/ 257;\" alt=\"\" \/><\/div><\/div><\/div>[\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_empty_space][vc_column_text css=&#8221;&#8221;]Funded by the Federal Republic of Germany<br \/>\nFunding organisation: Federal Ministry for Economic Affairs and Climate Protection on the basis of a resolution of the German Bundestag.<\/p>\n<p style=\"margin: 0in; font-family: Calibri; font-size: 11.0pt;\">The activities were funded as part of the LuFo VI-3 programme through the UpLift project.<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text]The global climate targets require, among other things, a massive reduction in greenhouse gas emissions, including in aviation. Hydrogen as an alternative energy source for aircraft is a promising solution as, unlike jet-fuel, it causes hardly any direct climate-damaging emissions. One of the biggest challenges is the storage of liquid hydrogen (LH2) at extremely low&hellip;<\/p>\n","protected":false},"author":106,"featured_media":6067,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[228],"tags":[335,338,242],"coauthors":[171,320],"class_list":["post-6495","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-artikel-en","tag-aviation","tag-hydrogen-en","tag-testing-en","category-228","description-off"],"_links":{"self":[{"href":"https:\/\/leichtbau.dlr.de\/en\/wp-json\/wp\/v2\/posts\/6495","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/leichtbau.dlr.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/leichtbau.dlr.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/leichtbau.dlr.de\/en\/wp-json\/wp\/v2\/users\/106"}],"replies":[{"embeddable":true,"href":"https:\/\/leichtbau.dlr.de\/en\/wp-json\/wp\/v2\/comments?post=6495"}],"version-history":[{"count":6,"href":"https:\/\/leichtbau.dlr.de\/en\/wp-json\/wp\/v2\/posts\/6495\/revisions"}],"predecessor-version":[{"id":6530,"href":"https:\/\/leichtbau.dlr.de\/en\/wp-json\/wp\/v2\/posts\/6495\/revisions\/6530"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/leichtbau.dlr.de\/en\/wp-json\/wp\/v2\/media\/6067"}],"wp:attachment":[{"href":"https:\/\/leichtbau.dlr.de\/en\/wp-json\/wp\/v2\/media?parent=6495"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/leichtbau.dlr.de\/en\/wp-json\/wp\/v2\/categories?post=6495"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/leichtbau.dlr.de\/en\/wp-json\/wp\/v2\/tags?post=6495"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/leichtbau.dlr.de\/en\/wp-json\/wp\/v2\/coauthors?post=6495"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}